The connections must be performed in compliance with the legal standards in force. Check
that the relief valve and the electrical system are able to support the load of the appliance (see
the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case, “standardised”
plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue wire must be used for the neutral,
- the brown wire must be used for the phase; the cable must not come into contact with hot
parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a suitable power
outlet.
For appliances that come supplied with cable and plug please ensure they are plugged into a
circuit suitable for this appliance.
Please refer to a qualifed person. (See technical specifications in point B).
The manufacturer declines all liability if the safety standards are not observed.
E
RANGE HOOD WITH OUTSIDE DISCHARGE
(exhaust)
In this version, the fumes and steam from the kitchen are conveyed outside through an exhaust
duct.
The exhaust conveyor that protrudes from the upper part of the range hood must be connected
to a duct that carries the fumes and steam outside. In this version, the charcoal filters, if fitted,
should be removed; to do this, see the instructions in point F. There must be adequate ventila-
tion of the room when the range hood is used at the same time as appliances burning gas or
other fuels, according to the standard.
Deviation for Germany:
When the range hood and appliances supplied with energy other than electricity are simulta-
neously in operation, the negative pressure in the room must not exceed 4 Pa (4x10 E-5 bar).
F
HOOD VERSION WITH INTERNAL RECIRCULA-
TION (filtering)
In this model, the area passes through the carbon filters to be purified and is then introduced
into the kitchen environment. To mount the filters, refer to section H2.
G
OPERATION
1: TIMER - FILTER RESET - SHUTTER OPENING - SHUTTER CLOSING
Timer: With the motor running, pressing this key will enable timed motor shut-down after 15 min-
utes. At the end of the 15 minutes the motor and the light will switch off and the mobile part
will close back up. The red LED flashes to indicate that the function is enabled. Varying the
speed of the motor will not interrupt the count. If the motor is stopped using key 4, the func-